Ross tech vcds vw tdi

broken image
broken image

MVB 075.1: Exhaust Gas Temperature before Turbo Charger MVB 070.1: Regeneration Status (xxxxxxx1 = Normal Regeneration active, xxxxxx1x = Forced Regeneration active) In case the regeneration fails there can either be problems with the Driving Cycle Conditions or with the Engine Hardware. Exhaust Gas Temperature before Turbo Charger above 700 ☌ĭrive the car based on the above conditions until the Particle Filter Load is as low as possible (close to 0 %).Engine Speed between 1500-2500 RPM (4th or 5th Gear, Automatic Transmission in Tiptronic).Vehicle Speed between 30-60 km/h (18-37 MPH).Power Consumers ON (Light, Seat Heating, Front/Rear Window Heater, Climate Control).If the Particle Filter Load is above Specification the Particle Filter needs to be replaced since the car may burn down when regenerating.Particle Filter Load below Specification (see Measure Value Block group 075, field 3, VCDS should give the specified value).Coolant Temperature above 50 ☌ (see Measure Value Block group 002, field 4).

broken image